TROUBLESHOOTING
CUTMASTER 42
Manual 0-5171
6-15 Troubleshooting
J8
1
Power source of fan
24VDC
2
0VDC(fan negative)when fan is on
0VDC
J9
1
N/A
N/A
2
GND
0VDC
3
Pilot ARC current feedback signal
-0.8VDC
+5VDC( A main cutting arc is established)
J10
1
Positive of voltage feedback
Machine output +
2
Negative of voltage feedback
Machine output _
J11
1
+12VDC
+12VDC
2
Pilot ARC IGBT drive signal
J12
1
N/A
N/A
2
Thermostat (0VDC when thermostat
closed)
3
GND
0VDC
J13
1
Pressure switch signal
Pressure switch(0dc when switch closed
otherwise 4VDC)
2
GND
0VDC
J14
1
GND
0VDC
2
Gun switch signal
0VDC when switch on otherwise 27VDC
3
Cup test signal
0VDC
4
Cup test signal
0VDC when the cup is fixed otherwise 27VDC