Section 6: troubleshooting, 01 basic troubleshooting-power source faults, Troubleshooting cutmaster 42 – Tweco 42 CutMaster Service Manual User Manual

Page 37

Advertising
background image

TROUBLESHOOTING

CUTMASTER 42

Manual 0-5171

6-1 Troubleshooting

6.01 Basic Troubleshooting-Power Source Faults

!

WARNING

There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to diagnose

or repair it unless you are an accredited service provider and you have had training in power electronics
measurement and troubleshooting techniques.

Common Faults symptom LED Indicators
A. AC indicator

OFF

1. Main input power cord does not connect to power distribution net.

a.

Connect the power cord.

2. Power ON/OFF switch in OFF (down) position.

a.

Turn switch to ON (up) position.

3. Actual input voltage does not correspond to voltage of unit.

a.

Verify that the input line voltage is correct.

4. Faulty components in unit

a.

Return for repair or have qualified technician repair per service manual.

B. AC indicator

blinking

1. Indicator blinking (1 sec ON/1 Sec OFF, Gas may also pulse 3 times).

a.

Check for missing torch parts or not properly installed. Turn ON/OFF switch to OFF position and restart

the machine by turning the power switch to ON.

2. Indicator blinking (1 sec ON/3 Sec OFF).

a.

Check for worn or sticking torch parts. Replace if necessary.

3. Indicator blinking (3 sec ON/3 Sec OFF).

a.

Torch switch was depressed before machine was completely powered up. Turn ON/OFF switch to OFF

position and the restart the machine by turning the power switch to ON.

C. Air indicator

OFF

1. Gas pressure too low. Check supply pressure.

D. TEMP indicator

ON, (AC indicator

ON)

1. Unit air flow obstructed.

a.

Check for blocked air flow around the unit and correct condition.

2. Fan blocked.

a.

Check for blocked status and correct condition.

SECTION 6:

TROUBLESHOOTING

Advertising