03 primary input power connections, Cutmaster 42 installation – Tweco 42 CutMaster Service Manual User Manual
Page 22
CUTMASTER 42 INSTALLATION
Installation 3-2 Manual 0-5171
3.03 Primary Input Power Connections
Power Cords Included With Power Supply
Attached to the power supply is an input power cord with a 230 Volt 50 Amp NEMA 6-50P for plug. Supplied adapters
allow for connection of the power supply input cable plug for when using 120V input power.
Art# A-09432_AB
Figure 3-1 120VAC Adapter Pigtail
CAUTION
Check your power source for correct voltage before plugging in or connecting the unit. The primary power
source, fuse, and any extension cords used must conform to local electrical code and the recommended
circuit protection and wiring requirements as specified in Section 2.
Input Voltage (VAC)
Rated Output
Amps (RMS) input at rated out-
put, 60 Hz, single-phase
kVA
120V, 15A Circuit
20A, 88V
20.4
2.5
120V, 20A Circuit
27A, 91V
28.5
3.5
120V, 30A Circuit
27A, 91V
28.5
3.5
208-230V, 20A Circuit
40A, 96V
23-21.4
4.8