03 primary input power connections, Cutmaster 42 installation – Tweco 42 CutMaster Service Manual User Manual

Page 22

Advertising
background image

CUTMASTER 42 INSTALLATION

Installation 3-2 Manual 0-5171

3.03 Primary Input Power Connections

Power Cords Included With Power Supply
Attached to the power supply is an input power cord with a 230 Volt 50 Amp NEMA 6-50P for plug. Supplied adapters

allow for connection of the power supply input cable plug for when using 120V input power.

Art# A-09432_AB

Figure 3-1 120VAC Adapter Pigtail

CAUTION

Check your power source for correct voltage before plugging in or connecting the unit. The primary power

source, fuse, and any extension cords used must conform to local electrical code and the recommended

circuit protection and wiring requirements as specified in Section 2.

Input Voltage (VAC)

Rated Output

Amps (RMS) input at rated out-

put, 60 Hz, single-phase

kVA

120V, 15A Circuit

20A, 88V

20.4

2.5

120V, 20A Circuit

27A, 91V

28.5

3.5

120V, 30A Circuit

27A, 91V

28.5

3.5

208-230V, 20A Circuit

40A, 96V

23-21.4

4.8