CUTMASTER 42 INSTALLATION

Installation 3-6 Manual 0-5171

3.06 Input Wiring Specifications

CUTMASTER 42 Input Power Requirements

Input

Power Input

Current Input Current Input Suggested Sizes (See Note)

Voltage

Freq.

(kVA)

Max (Amps)

Ieff (Amps)

Fuse (Amps)

(Volts-AC)

(Hz)

1-Ph

1-Ph

1-Ph

1-Ph

120

50/60

3.3

27.5

15

20

208

50/60

5.0

24

15.4

20

230

50/60

5.0

21.4

13.5

20

240

50/60

5.0

20.8

13

20

Line Voltages with Suggested Circuit Protection
Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements

for your situation in this regard.

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations.
Cable conductor temperature used is 167° F (75° C).