background image

Manual 0-5056 Ultra-Cut 200

7-3

TORCH INFORMATION

7.04 Torch Consumables Installation

Art # A-03887

W ARNINGS

Do not install consumables into the Cartridge

while the Cartridge is attached to the T

orch Head.

Keep foreign materials out of the consumables

Handle all parts carefully to avoid damage,

which may affect tor

ch per

formance.

1. Install the consumables as follows:

Cartridge Covers
Upper O-Ring
on Torch Tip

Shield Cap Protrudes
0.063-0.083" (1.6 - 2.1 mm)

Electrode

Plasma Gas
Distributor

Tip

Shield Gas
Distributor

Shield Cap

Upper O-Ring

on Tip

1: Stack Parts

2: Press Cartridge onto Stacked Parts

4: Check Shield Cap Protrusion

Art # A-04716

No Gaps

Between Parts

3: Thread Shield Cup onto Cartridge

Shield Cap

Shield Cup

Advertising