04 torch consumables installation, 04 torch consumables installation -3 – Tweco 200 Ultra-Cut User Manual
Page 115
Advertising
Manual 0-5056 Ultra-Cut 200
7-3
TORCH INFORMATION
7.04 Torch Consumables Installation
Art # A-03887
W ARNINGS
Do not install consumables into the Cartridge
while the Cartridge is attached to the T
orch Head.
Keep foreign materials out of the consumables
Handle all parts carefully to avoid damage,
which may affect tor
ch per
formance.
1. Install the consumables as follows:
Cartridge Covers
Upper O-Ring
on Torch Tip
Shield Cap Protrudes
0.063-0.083" (1.6 - 2.1 mm)
Electrode
Plasma Gas
Distributor
Tip
Shield Gas
Distributor
Shield Cap
Upper O-Ring
on Tip
1: Stack Parts
2: Press Cartridge onto Stacked Parts
4: Check Shield Cap Protrusion
Art # A-04716
No Gaps
Between Parts
3: Thread Shield Cup onto Cartridge
Shield Cap
Shield Cup
Advertising