Tweco 200 Ultra-Cut User Manual
Page 48
Advertising
Manual No. 0-5056 Ultra-Cut 200
3-24
INSTALLATION
Installation
The Remote Arc Starter must be installed in a suitable location near the torch head.
If the Arc Starter is mounted
to a gantry or to any other support subject to motion or vibration, fasten the Arc Starter to the support securely.
1. Loosen, but do not remove, the lower screws securing the cover to the Arc Starter. Remove the upper
screws securing the Cover Panel to the Arc Starter.
NOTE
A ground wire connects the cover to the Arc Starter base. This wire must remain in place.
2. Remove the Cover Panel from the Arc Starter.
Art # A-09625
Lower screws
(2 per side)
Upper screws (2 per side)
Cover
Ground Wire
Cover Removal