Manual 0-5056 Ultra-Cut 200

A-12

APPENDIX

5

+10V @ 10ma. For Remote CC Pot

– Previously CCM versions if one wanted to use a potentiometer for the Remote

Analog Current Control (CC) input an external 10 V supply was required for Pot High.. Now an isolated (from main
plasma circuits) 10V supply is provided. Recommended value of the pot is 5K or 10K.

Ext. +10V

11

10

9

TB1

+10V

WIPER

Art # A-09246

5

Plasma Marking Select (Remote)

– Plasma Marking, available only with DFC 3000, may be activated with a contact

closure between TB3-1 & TB3-2 if SW8-4, DIP switch on the CPU board (smaller of the 2 CCM boards), is also on.
Opening the connection between TB3-1 & TB3-2 switched back to normal cutting mode. For Ultracut power supplies
It is OK to leave SW8-4 on whether you are marking or not.