10 connect fiber optic cable, 10 connect fiber optic cable -14 – Tweco 200 Ultra-Cut User Manual
Page 38
Advertising
Manual No. 0-5056 Ultra-Cut 200
3-14
INSTALLATION
3.10 Connect Fiber Optic Cable
Check the type of internal control module.
1. Connect one end of each cable to the power supply as shown.
a. Remove the strain relief securing nut from the strain relief on the fiber optic cable(s). Loosen the strain
relief dome nut from the strain relief.
b. Pass the cable connector through the appropriate opening. Slide the strain relief securing nut onto the
cable. Make a loop of the cable; carefully press the cable connector into the appropriate receptacle on the
internal control module.
c. Tighten the strain relief onto the cable(s). Do not overtighten.
Thin nut securing
the through hole
protector
Fiber Optic
Cable
Plug
Art # A-09456
Advertising