Manual No. 0-5056 Ultra-Cut 200

3-14

INSTALLATION

3.10 Connect Fiber Optic Cable

Check the type of internal control module.

1. Connect one end of each cable to the power supply as shown.

a. Remove the strain relief securing nut from the strain relief on the fiber optic cable(s). Loosen the strain

relief dome nut from the strain relief.

b. Pass the cable connector through the appropriate opening. Slide the strain relief securing nut onto the

cable. Make a loop of the cable; carefully press the cable connector into the appropriate receptacle on the
internal control module.

c. Tighten the strain relief onto the cable(s). Do not overtighten.

Thin nut securing
the through hole
protector

Fiber Optic
Cable
Plug

Art # A-09456