4.01 Power Supply Control Panel

Art # A-04862

AC Indicator

Temp Indicator

Gas Indicator

DC Indicator

Status Indicator

Indicates AC power is being supplied to the inverters when the ON/OFF switch is in ON position. When
switch is first set to ON, the indicator stays off until the inrush cycle is complete and the correct voltage is
confirmed.

Normally OFF. Indicator turns ON when the internal temperature sensors detect tempera-

tures above normal limits. Let the unit cool before continuing operation.

Normally ON. Indicates gas control is ready for operation. The indicator blinks during the

purge cycle or when the gas control is not in the RUN mode or when there is a communication error. Indicator
is off when there is no call for gas flow.

Indicates the power supply is generating output DC voltage.

!

Shows system status. The number of flashes indicates the status. Refer to the Status

Code Section for details. On power supply start-up, the indicator flashes to show the revision level of the
operating software installed in the system.