OPERATION

Adjusts the output current of the power supply.

High Precision

Plasma Cutting System

PREFLOW

H

2

O

MIST

PLASMA

SHIELD

PRESSURE

PLASMA

POWER SUPPLY

GAS

FLOW

High Precision

Plasma Cutting System

ENABLE

DISABLE

GAS

MODE

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

O2 - AIR

O2 - O2

H35 -N

2

F5 - N

2

AIR - AIR

N

2 -

H

2

O

N

2 -

N

2

9

9

Art # A-04767

GCM

2010

The DISABLE position removes input power from the Power Supply inverters, disables the coolant pump and
fan, the pilot contactor & HF and removes AC power from the gsa control solenoids shutting off all gas flow.
When the switch is returned to the ENABLE position an automatic gas purge is started and then the system is
returned to normal operation under control of the CNC device.

Used to set preflow gas pressure and flow. MODE switch must be in SET PREFLOW position.

Used to set plasma and shield gas pressures and flows. Mode switch must be in SET PLASMA & SHIELD
position.

At lower flow rates shield gas pressure is first set per the cut charts then the flow is set using the flow meter
with the GAS switch set in the FLOW position. Some torch parts require higher flow rates that execeed the
capacity of the flow meter. In that case, Gas switch is set in the PRESSURE position and the regulator and
gauge is used to set pressure per the cut charts when no “Ball” setting is shown.

Used to set water flow rate. MODE switch must be in SET PLASMA & SHIELD position. GAS selection switch
must be in N

2

-H

2

O position.

Water mist is not used in all applications.