Manual No. 0-5056 Ultra-Cut 200

3-22

INSTALLATION

3.15 Gas Control Module: Control, Input, and Output Connections

1. Make all other connections to the rear of the Module. The connections are labeled. The Module must be

grounded; the grounding terminal is marked Use #10 AWG (European 6 mm

2

) (or thicker) wire for

grounding. Keep the ground wire as short as possible.

2. Position the Module on a flat, horizontal, mounting surface.

3. Ensure that the Flowmeters are plumb.

4. Secure the Module to the mounting surface.

5. Connect all gas / water inputs to the rear panel of the module.

6. Connect the appropriate control cables to terminals marked ‘TVA’ (torch valve assembly) and ‘power sup-

ply’.

Gas & Water Inputs (Check Valves)

Connection Panel

To Torch Valve Assembly

To Torch Valve Assembly

To Power Supply

SHIELD

PLASMA

PREFLOW

H O

SHIELD

2

H O

2

AIR

N2

O2

H35

F5

TVA

POWER
SUPPLY

COMM

J57

J56

INPUTS

When Cutting With O2 Plasma

Air MUST BE Connected

Ground Stud

SHIELD

PLASMA

PREFLOW

H O

SHIELD

2

H O

2

AIR

N2

O2

H35

F5

TVA

POWER
SUPPLY

COMM

J57

J56

INPUTS

When Cutting With O2 Plasma

Air MUST BE Connected

Gas Control Box
Rear Panel

Art # A-06881