07 connect work cable and pilot and negative leads – Tweco 200 Ultra-Cut User Manual
Page 35
Advertising

Manual No. 0-5056 Ultra-Cut 200
3-11
INSTALLATION
3.07 Connect Work Cable and Pilot and Negative Leads
1. Pass the ends of the work cable and pilot and negative leads upward through the leads bracket at the
bottom edge of the rear panel, then through the openings in the connections cover support panel.
2. Refer to the illustration. Connect the leads as shown. Tighten securely. Do not overtighten.
The clear connections cover must remain in place.
PILO
T
WORK
TORCH
Connection Panel
AC INPUT
L1
L
2
L3
Work Lead
Torch Lead - To Remote Arc Starter
Work
Torch
Lead Connection Detail
Connections Cover
Support Panel
Art # A-07660_AB
Connections Cover
Pilot
To Cutting Table
Leads Bracket
Pilot Lead -
To Remote Arc Starter
Advertising