Manual No. 0-5056 Ultra-Cut 200

3-32

INSTALLATION

3.17 Original & XTL Torch Valve Installation

General Information

This assembly mounts as close as possible to the torch head. It accepts preflow, plasma, and shield gases from
the Gas Control Module and supplies these gases to the Torch.

Mounting

1.450”

36.83 mm

4.450”

113.03 mm

.261” Dia.

6.63 mm

Art # A-07648

1. Mount the Valve Kit as close as possible to the Torch. The valve kit can be mounted in any convenient

position, provided the outlet side (with two fittings) is closer to the torch than the inlet side (with three fittings
and a control cable connector).

2. Connect the Valve Kit outlets to the torch leads as shown. (XTL shown)