Manual No. 0-5056 Ultra-Cut 200

4-12

OPERATION

Error

Code

Error

Remedy / Comments

2-1

Missing Phase

Blown fuse, Broken or loose connection on power cable

2-2

Wrong input voltage

Inverter(s) not configured correctly for input voltage;
Poor power quality (brownouts, dropouts); Input power capacity / wiring
too small causing voltage drop; broken or loose power cable
connections.

2-3

Inverter or Pilot Regulator Over
Temperature

Failed fan; Ambient above 40 deg C. (104 F); Blocked airflow

2-4

Power Supply not Ready

Defective inverter

2-5

DC Output Low

Output less than 60 VDC; Defective inverter, shorted output; Shorted pilot
regulator (chopper); CCM voltage sense (J6) wire open or disconnected.

2-6

Primary over current fault

Over current detected in inverter primary circuit, remove power to reset;
defective inverter; voltage surge;

2-7

Unexpected current

Current >20A in work or pilot leads before pilot ignition; Possible shorted
torch; Defective current sensor.

2-8

Unexpected current in pilot
circuit

Current > 5A in pilot circuit; wrong or mismatched consumables; Pilot
lead shorted to negative in torch tube; Possible shorted torch

2-9

Unexpected current in work
lead

Current > 5A in work lead; Short to chassis in RAS; Negative lead short to
ground.

3-1

Gas Control Communication
fault, Cannot establish
Communication with gas
control.

If GCM 1000: Control cable not connected or Basic ID signal open.
GCM 2010 & 2000: Dirt on fiber ends or in connectors, blow out with
clean dry air; fiber not locked into connector; sharp bends in fiber; fiber
defective; Gas Control PCB defective, replace. CCM defective, replace.

3-2

Gas Control Communication
reply fault, connection was
established but CCM did
receive a reply to a process
request.

Gas Control did not reply to signal from CCM in allowed time. Dirt on
fiber ends or in connectors, blow out with clean dry air; fiber not locked
into connector; sharp bends in fiber; fiber defective. If problem persists
Gas Control PCB likely defective, replace board.

3-3

Gas Pressure Low

If GCM 1000, Plasma < 15 PSI; faulty or disconnected pressure SW.
If GCM2010_AG, GCM2000_AC or later or Gas Control has been
updated with 19X2219_AG or later PCB: Plasma or Shield input out of
range 105-135.
If GCM2010_AG, GCM2000_AC or later or Gas Control has been
updated with 19X2219_AG or later PCB: Plasma or Shield input out of
range 105-135 PSI; Unplugged or Faulty pressure sensor.

3-4

Gas Control not ready

Purging; not in RUN mode; Gas Control faulty, replace PCB.

3-5

Gas Control Protocol Fault

Application error or firmware compatibility fault

3-6

Invalid Current Control level
from GCM

GCM sent output current level outside the range of the power supply,
Check firmware compatibility

3-7

Gas Control returns wrong
command sequence

Check firmware compatibility

3-8

CCM and Gas Control type
(Autocut-Ultracut) mismatch

Install correct CCM or Gas Control for system

3-9

Gas Control Communication
reply fault

Reply not compatible with request; Check firmware compatibility

3-10

Warning. -- Gas Control
firmware needs update

System will function but control may not be optimized for best
performance / consumable life

Fault Code Key