18 connecting torch, 18 connecting torch -33 – Tweco 200 Ultra-Cut User Manual

Page 57

Advertising
background image

Manual No. 0-5056 Ultra-Cut 200

3-33

INSTALLATION

Art # A-07645

Do not remove brass plugs
Front and side

Right-hand Thread:

To Torch Shield Gas fitting

Left-hand Thread:

To

Torch

Plasma Gas fitting

Outlet Side

3. Connect the gas supply lines and the control cable connector from the Gas Control Module to the Valve Kit as

shown. Hold the check valves stationary while attaching the gas lines. (XTL shown)

Control Cable

Plasma Gas Inlet

Shield Gas Inlet

Preflow Gas Inlet

WMS™ Inlet

Art # A-07646

Exhaust Muffler

Hold all fittings stationary while attaching hoses or leaks can be created. Side pressure can break the check valves
or weaken their connection to the torch valve assembly. All fittings must be checked for leaks after assembly.