Thermal dynamics, Key plug – Tweco 200 Ultra-Cut User Manual

Page 145

Advertising
background image

Manual 0-5056 Ultra-Cut 200

A-27

APPENDIX

6

6

7

7

8

8

9

9

10

10

A

B

C

D

E

F

PLASMA ENABLE

PRESS OK (GCM 1000)

24VAC

24 VAC

R

E

T

PLASMA ENABLE

+15V

/ AC

/ TEMP

/ STATUS

/ DC

/ GAS - COOLANT

POT HI (GCM1000)

POT WIPER (GCM1000)

POT LOW (GCM 1000)

- ARC V

- ARC V

WORK

DC 15V

DC 0V

AC120V-RAS

0V-RAS (120V ret)

0V-A (24V ret)

NEG ARC VOLTS

NEG

ARC VO

LTS

AC24V-GCM

AC24V-GCM

0V-A (24V ret)

AC120V-GCM

0V-B (120V ret)

PI

LOT (TIP) VO

LTS

0V-B (120V ret)

WORK

AC120V-GCM

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE: UNLESS OTHERWISE SPECIFIED -

1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.
2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).

Chk:

App:

TITLE:

Last Modified:

Size

SCHEMATIC,

Thermal

Dynamics

AA

42X1217

Friday, September 25, 2009

2

2

Industrial Park #2
West Lebanon NH 03784
603-298-5711

150/200A Power Supply 400V CE (Chopper)

Tuesday, October 03, 2006

08:11:44

Thermal Dynamics

D

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE: UNLESS OTHERWISE SPECIFIED -

1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.
2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).

Chk:

App:

TITLE:

Last Modified:

Size

SCHEMATIC,

Thermal

Dynamics

AA

42X1217

Friday, September 25, 2009

2

2

Industrial Park #2
West Lebanon NH 03784
603-298-5711

150/200A Power Supply 400V CE (Chopper)

Tuesday, October 03, 2006

08:11:44

Thermal Dynamics

D

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE: UNLESS OTHERWISE SPECIFIED -

1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.
2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).

Chk:

App:

TITLE:

Last Modified:

Size

SCHEMATIC,

Thermal

Dynamics

AA

42X1217

Friday, September 25, 2009

2

2

Industrial Park #2
West Lebanon NH 03784
603-298-5711

150/200A Power Supply 400V CE (Chopper)

Tuesday, October 03, 2006

08:11:44

Thermal Dynamics

D

DAT

ECO-B402 DAT 2/26/07

AB

ECO-B448 DAT 4/13/07

ECO-B646 GAC 10/31/07

AC

4-24-09

DAT

ECO-B1391

AD

DAT

AE

(E2)

MOMENTARY START / STOP

START / STOP

* REMOTE MARKING -

STOP

START

* Only in CCM w/
19X2634 I/O PCB.
Remote Marking
only for DFC 3000
(not isolated)

Rx-

Tx+

Rx+

Tx-

Signal & GND
Isolated from
Plasma Supply

INTERNAL TERMINAL
STRIP TB3

KEY PLUG

TB1

TB2

(C9, sht 1)

+

-

RS 485 (2 wire)
uses Tx+ & Tx- only
(used for TSC 3000)

Signal - Basic ID
Used to identify
GCM 1000 present

RIBBON CABLE

TEST SOCKET

RS 422 (4 wire)
connect TX+ to RX+
of CNC, Tx- to Rx-
of CNC

DIVIDED ARC V +

(E2)

(E2)

DIVIDED ARC V -

REMOTE ANALOG CURRENT CONTROL -

REMOTE ANALOG CURRENT CONTROL +

JUMPER IN
REMOTE
HMI

** RS 485 / 422
on CPU board
19X2554 only.

(A9, sht1)

(B9, sht1)

(C9, sht1)

TB3

KEY PLUG

Was 7 pin
changed to
14 pin in 2009

(E4)

(F4)

CN11 34 CKT

CN10 26 CKT

START / STOP

DIVIDED ARC VOLTS

PILOT ON
OUTPUT

REMOTE ANALOG
CURRENT CONTROL

* OK2

Iso

J36 34 CKT

PCB6 DISPLAY
WK-5603

JUMPER
for 2 WIRE
(RS485 only)
wire to A & B

4W

4W

2W

JUMPER
for 4 WIRE
uses
TX+, TX-
RX+, RX-

J35 26 CKT

J14

J14

2W

SW14

SW14 - LINE
TERMINATION
normally on
(refer to manual)

* OK2

RIBBON CABLE

5

9

8
7

6

1

2
3

4

SW10-ADDRESS

normally 0

(refer to

manual)

0

TEST SOCKET

HOLD START -
HOLD START +

(A9, sht 1)

UNDIVIDED ARC VOLTS
FOR HEIGHT CONTROLS

* +10VDC @ 10 ma.(for CC pot high)

OK TO MOVE

GND

GND

& CNC COMM

PREFLOW ON -
PREFLOW ON +

PLASMA ENABLE

24 VAC @ 1A

120 VAC @ 100ma.

(Not in all units)

OK to MOVE -

POWER SUPPLY
REAR PANEL

E-STOP -
E-STOP +

* REMOTE MARKING +

RIBBON CABLE SIGNALS
/ = active low digital signal

CN10-J35 - 26 Ckt Ribbon Cable

2-Cut Demand
4-Pilot Demand
6-/ Start
7-/ Start2
9-/ Pilot Enable
10-/ HF Enable
12-/ Pump Enable
13-/ Fan Enable
15-/ DC Indicator
16-/ Over Temperature Indicator
18-/ Gas-Coolant OK Indicator
19-/ Status Lamp

CN11-J36 - 34 Ckt Ribbon Cable

1- Output Current Signal
3- / Arc Transferred (CSR)
4- / Pilot On
6- Coolant Flow (freq)
7- Coolant Temp (analog)
9- / Temp OK (Inverter/Chopper)
10- / Coolant Level OK
12- Missing Phase
13- / Ready to Operate
15- / Input Volts OK
16- / Inverter OCR
18- / PS ID "00*"
19- / PS ID "0*0"
20- / PS ID "*00"
21- E-Stop
22- E-Stop
29,31,33- 24 VAC Supply
30,32,34- 24 VAC Return

Rx-

Tx+

Rx+

Tx-

OK to MOVE +

ECO-B1535

9-25-09

1

1

2

2

100K3

100K3

7

7

1

1

3

3

1

1

J6

J6

1

5

8

TP11

TP11

6

6

TP1

TP1

GAS ON

GAS ON

J15-CNC

J15-CNC

1

2

3

4

5

6

7

8

9

10

11

12

13

14

100K

100K

2

2

2

2

CN23

CN23

1

2

3

4

5

6

9

9

8

8

J59-RAS

J59-RAS

1

2

3
4
5
6

7

8

9

10
11
12
13
14

GREEN1

GAS

GREEN1

GAS

J6 **

J6 **

1

2

3

4

5

6

J54-REMOTE HMI

J54-REMOTE HMI

1

2

3

4

5

6

7

8

9

10

11

12

13

14

5

5

OK2 *

OK2 *

3

3

11

11

8

8

10

10

1K

1K

2

2

10

10

4

4

10

10

3

3

J1

J1

1

2

3

4

5

6

7

8

9

9

9

PSR

PSR

12

12

12

12

4

4

GREEN

AC

GREEN

AC

9

9

11

11

J8

J8

1

2

3

4

1

1

11

11

GREEN2

DC

GREEN2

DC

K7-1

K7-1

5

5

6

6

E-STOP

E-STOP

J7

J7

1

2

3

4

5

6

7

8

9

J9

J9

1

2

3

4

5

6

12

12

4

4

J55-GCM

J55-GCM

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37

5

5

TP13

TP13

J4

J4

1

3

5

7

7

7

7

7
8

8

6

6

K6

K6

J5

J5

1

2

3

4

5

CN24

CN24

1

2

3

4

5

6

YELLOW

TEMP

YELLOW

TEMP

RED

STATUS

RED

STATUS

Art # A-07009_AD

Advertising