Tweco 200 Ultra-Cut User Manual
Page 63
Advertising
Manual No. 0-5056 Ultra-Cut 200
3-39
INSTALLATION
7.
Connect the wire lead from the height finder to the ohmic clip if using ohmic torch height
sensing.
Ohmic Clip
Art # A-03393_AB
Ohmic height sensing is not recommended with water shield. Water on the plate interferes electrically with the
ohmic sensing circuit.
Advertising