06 specifications & electrical requirements, 07 system component layout – Tweco 200 Ultra-Cut User Manual

Page 18

Advertising
background image

Manual No. 0-5056 Ultra-Cut 200

2-2

SPECIFICATIONS

2.06 Specifications & Electrical Requirements

Maximum OCV (U

0

)

380 vdc

Maximum Output Current

200 Amps

Maximum Output Voltage

230 vdc

Duty Cycle Rating

100% @ 200A, 180vdc (36 kW),
@ 104F° (40°C) Ambient Temperature

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.70 @ 100 ADC Output

Cooling

Forced Air (Class F)

Ultra-Cut® 200 Power Supply Specifications

Input

Power Input

Current

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

60

46

130

160

#2

2

230

60

49

125

150

#2

2

400

50

53

77

100

#2

1

400 (CE)

50

54

77

100

#2

1

460

60

59

75

90

#2

1

600

50/60

52

51

70

#8

Ultra-Cut 200 Power Supply Electrical Inputs

2

Extra Hard Usage Type G, G-GC, W

Suggested Sizes (See Note)

Line Voltages with Suggested Circuit Protection and Wire Sizes

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

Based on National Electric Code and Canadian Electrical Code

2.07 System Component Layout

Refer to section 3.11 for ground connections and ground cables.

Primary power

Work

CNC

Remote

Arc

Starter

Art # A-07233_AB

Torch

Coolant Supply

Coolant Return

Control Cable

Pilot

Return

Coolant Supply

Coolant Return

Plasma Gas

Shield Gas

Work Cable

Fiber
Optic

Cable

Control

Cable

Gas Control

Module

Power
Supply

Torch

Valve

Assembly

Positioning Tube

Plasma Gas

Preflow Gas

Water Shield

Shield

Shield Gas

Negative

Pilot

Return

Control Cable

100’ / 30.5 m Maximum Length

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Shield

H

Q

R

T

S

A

B

C

D

E

P

K

L

O

I

J

G

175’ / 53.3 m Maximum Length

Advertising