Installing the chassis intrusion switch, D. see figure 3-21 – Dell PowerVault NX200 User Manual
Page 121
Advertising

Installing System Components
119
Figure 3-21. Removing and Installing the Chassis Intrusion Switch
Installing the Chassis Intrusion Switch
1 Align the chassis intrusion switch with the securing bracket notch.
See Figure 3-21.
2 Slide the switch into the securing bracket notch. See Figure 3-21.
3 Connect the chassis intrusion switch cable to the connector on
the system board.
4 Close the system. See "Closing the System" on page 80.
5 Place the system upright on a flat surface.
6 Reattach any peripherals and connect the system to an electrical outlet.
7 Turn on the system and attached peripherals.
1
chassis intrusion switch
2
chassis intrusion switch cable
3
intrusion connector on the
system board
1
2
3