Table 1-2. System Messages

Message

Causes

Corrective Actions

Alert! iDRAC6 not
responding.
Rebooting.

The iDRAC6 is not

responding to BIOS

communication either

because it is not functioning

properly or has not

completed initialization.

The system will reboot.

Wait for the system to

reboot.

Alert! iDRAC6 not
responding.
Power required
may exceed PSU
wattage.
Alert!
Continuing
system boot
accepts the risk
that system may
power down
without warning.

The iDRAC6 is hung.
The iDRAC6 was remotely

reset while system was

booting
After AC recovery, the

iDRAC6 takes longer than

normal to boot.

Remove AC power to the

system for 10 seconds and

restart the system.