Installing System Components

1 Unpack and prepare the drive for installation. For instructions, see the

documentation that accompanied the drive.

NOTE:

Each device attached to a SCSI host adapter must have a unique

SCSI ID number (narrow SCSI devices use IDs 0 to 7; wide SCSI devices

use IDs from 0 to 15). Set the drive's SCSI ID to avoid conflicts with other

devices on the SCSI bus. For the default SCSI ID setting, see the

documentation provided with the drive.

NOTE:

There is no requirement that SCSI ID numbers be assigned

sequentially or that devices be attached to the cable in order by ID number.

NOTE:

SCSI logic requires that the two devices at opposite ends of

a SCSI chain be terminated and that all devices in between be unterminated.

Enable the drive's termination if it is the last device in a chain of devices (or

sole device) connected to the SCSI controller.

2 Turn off the system, including any attached peripherals, and disconnect

the system from its electrical outlet.

3 Open the system. See "Opening the System" on page 79.
4 Remove the front bezel. See "Removing the Front Bezel" on page 75.
5 If you are installing a drive into an empty bay:

a

Remove the EMI filler panel. See "Removing an EMI Filler Panel" on

page 77.

b

Remove the front bezel insert. See "Removing the Front Bezel Insert"

on page 76.

If you are installing a new drive into a bay that has an optical drive, see

"Removing an Optical Drive" on page 90.