Troubleshooting Your System

4 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 55. Make any changes to the

memory settings, if needed.
If the memory settings match the installed memory but a problem is still

indicated, go to step 15.

5 Turn off the system and attached peripherals, and disconnect the system

from the electrical outlet.

6 Open the system. See "Opening the System" on page 79.
7 Remove the cooling shroud. See "Removing the Cooling Shroud" on

page 82.

8 Check the memory banks and ensure that they are populated correctly.

See "General Memory Module Installation Guidelines" on page 98.

9 Reseat the memory modules in their sockets. See "Installing Memory

Modules" on page 100.

10 Replace the cooling shroud. See "Installing the Cooling Shroud" on

page 83.

11 Close the system. See "Closing the System" on page 80.
12 Place the system upright.
13 Reconnect the system to its electrical outlet, and turn on the system and

attached peripherals.

14 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 55. If the problem is not resolved

proceed with the next step.

15 Turn off the system and attached peripherals, and disconnect the system

from the power source.

16 Open the system. See "Opening the System" on page 79.
17 If a diagnostic test or error message indicates a specific memory module as

faulty, swap or replace the module.

18 To troubleshoot an unspecified faulty memory module, replace the

memory module in the first DIMM socket with a module of the same type

and capacity. See "Installing Memory Modules" on page 100.

19 Close the system. See "Closing the System" on page 80.