Troubleshooting the power supply, Troubleshooting the – Dell PowerVault NX200 User Manual

Page 137

Advertising
background image

Troubleshooting Your System

135

1 Re-enter the time and date through the System Setup program. See "Using

the System Setup Program and UEFI Boot Manager" on page 51.

2 Turn off the system and disconnect it from the electrical outlet for

at least one hour.

3 Reconnect the system to the electrical outlet and turn on the system.
4 Enter the System Setup program.

If the date and time are not correct in the System Setup program,

replace the battery. See "Replacing the System Battery" on page 116.

NOTE:

Some software may cause the system time to speed up or slow down.

If the system seems to operate normally except for the time kept in the

System Setup program, the problem may be caused by software rather than

by a defective battery.

If the problem is not resolved by replacing the battery, see "Getting Help"

on page 157.

Troubleshooting the Power Supply

1 Identify the faulty power supply by the power supply's fault indicator.

See "Power Supply Indicator Codes" on page 22.

2 Reseat the power supply by removing and reinstalling it. See "Chassis

Intrusion Switch" on page 118.

NOTE:

After installing a power supply, allow several seconds for the system

to recognize the power supply and to determine if it is working properly.

The power indicator turns green to signify that the power supply is

functioning properly.

If the problem persists, replace the faulty power supply.

3 If the problem persists, see "Getting Help" on page 157.