Dell PowerVault NX200 User Manual

Page 27

Advertising
background image

About Your System

27

E1420 CPU Bus

parity error.
Power cycle
AC.

The system BIOS has

reported a processor

bus parity error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E1422 CPU # machine

check error.
Power cycle
AC.

The system BIOS has

reported a machine

check error.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E1610 Power Supply

# (### W)
missing.
Check power
supply.

Specified power supply

was removed or is

missing from the system.

See "Troubleshooting the

Power Supply" on page 135.

E1614 Power Supply

# (### W)
error. Check
power supply.

Specified power supply has

failed.

See "Troubleshooting the

Power Supply" on page 135.

E1618 Predictive

failure on
Power Supply
# (### W).
Check PSU.

A power supply fan failure,

an over-temperature

condition, or power supply

communication error has

caused the predictive

warning of an impending

power supply failure.

See "Troubleshooting the

Power Supply" on page 135.

E161C Power Supply

# (### W)
lost AC
power. Check
PSU cables.

Specified power supply is

attached to the system, but

it has lost its AC input.

Check the AC power

source for the specified

power supply. If the

problem persists,

see "Troubleshooting the

Power Supply" on page 135.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 27 Monday, August 9, 2010 3:07 PM