Dell PowerVault NX200 User Manual

Page 33

Advertising
background image

About Your System

33

E201C SMI

initializati
on failure.
Power cycle
AC.

System management

interrupt (SMI)

initialization failure.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E201D Shutdown test

failure.
Power cycle
AC.

BIOS shutdown

test failure.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E201E POST memory

test failure.
Check DIMMs.

BIOS POST memory test

failure.

See "Troubleshooting

System Memory" on

page 137.
If the problem persists,

see "Getting Help" on

page 157.

E2020 CPU

configuratio
n failure.
Check screen
message.

Processor configuration

failure.

Check screen for specific

error messages.

See "Troubleshooting the

Processor" on page 144.

E2021 Incorrect

memory
configur-
ation. Review
User Guide.

Incorrect memory

configuration.

Check screen for specific

error messages.

See "Troubleshooting

System Memory" on

page 137.

E2022 General

failure
during POST.
Check screen
message.

General failure after video. Check screen for specific

error messages.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 33 Monday, August 9, 2010 3:07 PM

Advertising