Dell PowerVault NX200 User Manual

Page 31

Advertising
background image

About Your System

31

E2011 Memory

configuratio
n failure.
Check DIMMs.

Memory detected, but is

not configurable.

Error detected during

memory configuration.

See "Troubleshooting

System Memory" on

page 137.

E2012 Memory

configured
but unusable.
Check DIMMs.

Memory configured,

but is unusable.

See "Troubleshooting

System Memory" on

page 137.

E2013 BIOS unable

to shadow
memory. Check
DIMMs.

The system BIOS failed

to copy its flash image

into memory.

See "Troubleshooting

System Memory" on

page 137.

E2014 CMOS RAM

failure.
Power cycle
AC.

CMOS failure.

CMOS RAM not

functioning properly.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E2015 DMA

Controller
failure.
Power cycle
AC.

DMA controller failure.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E2016 Interrupt

Controller
failure.
Power cycle
AC.

Interrupt controller failure. Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists, see

"Getting Help" on

page 157.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 31 Monday, August 9, 2010 3:07 PM