Dell PowerVault NX200 User Manual

Page 42

Advertising
background image

42

About Your System

Memory set to
minimum
frequency.

The memory frequency

may be intentionally set

lower for power conservation.

If not an intentional setting,

check any other system

messages for possible causes.

The current memory

configuration may

support only the

minimum frequency.

Ensure that your memory

configuration supports the

higher frequency.

See "General Memory

Module Installation

Guidelines" on page 98.

Memory tests
terminated by
keystroke.

POST memory test was

terminated by pressing the

spacebar.

Information only.

MEMTEST lane
failure
detected on

x

Invalid memory

configuration. A mismatched

memory module is installed.

Ensure that the memory

modules are installed in

a valid configuration.

See "General Memory

Module Installation

Guidelines" on page 98.

No boot device
available

Faulty or missing optical

drive subsystem, hard drive,

or hard-drive subsystem, or

no bootable USB key

installed.

Use a bootable USB key, CD,

or hard drive. If the

problem persists,

see "Troubleshooting an

Internal USB Key" on

page 139, "Troubleshooting a

USB Device" on page 130,

"Troubleshooting an Optical

Drive" on page 140, and

"Troubleshooting a Hard

Drive" on page 141.

See "Using the System Setup

Program and UEFI Boot

Manager" on page 51 for

information on setting the

order of boot devices.

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions

book.book Page 42 Monday, August 9, 2010 3:07 PM