Dell PowerVault NX200 User Manual

Page 49

Advertising
background image

About Your System

49

Warning: A fatal
error has caused
system reset!
Please check the
system event log!

A fatal system error

occurred and caused

the system to reboot.

Check the SEL for

information that was logged

during the error. See the

applicable troubleshooting

section in "Troubleshooting

Your System" on page 129 for

any faulty components

specified in the SEL.

Warning: Control
Panel is not
installed.

The control panel is not

installed or has a faulty

cable connection.

Install the control panel, or

check the cable connections

between the display module,

the control panel board,

and the system board. See

"Control Panel Assembly" on

page 120.

Warning! No micro
code update
loaded for
processor n

Micro code update failed.

Update the BIOS firmware.

See "Getting Help" on

page 157.

Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.

The system configuration of

processor, memory modules,

and expansion cards may

not be supported by the

power supply.

If any system components

were just upgraded,

return the system to the

previous configuration.

If the system boots without

this warning, then the

replaced component(s) are

not supported with this

power supply. See "Chassis

Intrusion Switch" on

page 118.

Table 1-2. System Messages

(continued)

Message

Causes

Corrective Actions

book.book Page 49 Monday, August 9, 2010 3:07 PM