Dell PowerVault NX200 User Manual

Page 28

Advertising
background image

28

About Your System

E1620 Power Supply

# (### W) AC
power error.
Check PSU
cables.

Specified power supply's

AC input is outside of

the allowable range.

Check the AC power

source for the specified

power supply. If the

problem persists,

see "Troubleshooting the

Power Supply" on page 135.

E1629 Power

required >
PSU wattage.
Check PSU and
config.

The system configuration

requires more power

than the power supply can

provide, even with

throttling.

Turn off power to the

system, reduce the

hardware configuration or

install higher-wattage

power supply, and then

restart the system.

E1710 I/O channel

check error.
Review &
clear SEL.

The system BIOS has

reported an I/O channel

check.

Check the SEL for more

information and then

clear the SEL.

Remove AC power to

the system for 10 seconds

and restart the system.
If the problem persists,

see "Getting Help" on

page 157.

E1711 PCI parity

error on Bus
## Device ##
Function ##

The system BIOS has

reported a PCI parity error

on a component that

resides in PCI

configuration space at

bus ##, device ##,

function ##.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 143.

PCI parity
error on Slot
#. Review &
clear SEL.

The system BIOS has

reported a PCI parity error

on a component that

resides in the specified slot.

Remove and reseat the

PCIe expansion cards.

If the problem persists,

see "Troubleshooting

Expansion Cards" on

page 143.

Table 1-1. LCD Status Messages

(continued)

Code

Text

Causes

Corrective Actions

book.book Page 28 Monday, August 9, 2010 3:07 PM

Advertising