Step 20, i – Dell POWERVAULT MD3620I User Manual

Page 265

Advertising
background image

Troubleshooting: Your Storage Array Software

263

If you started the host system before you were connected to the RAID

controller module in the storage array, the Host Context Agent software is

not able to detect the RAID controller modules. If this is the case, make

sure that the connections are secure, and restart the Host Context Agent

software.

19 If you have recently replaced or added the RAID controller module, restart

the Host Context Agent software so that the new RAID controller module

is recognized.

20 If the problem still exists, make the appropriate host modifications, check

with other administrators to see if a firmware upgrade was performed on

the RAID controller module from another storage management station.
If a firmware upgrade was performed, the EMW on your management

station may not be able to locate the new AMW software needed to

manage the storage array with the new version of the firmware.

21 If the problem persists contact your Technical Support representative.
22 Determine if there is an excessive amount of network traffic to one or

more RAID controller modules.
This problem is self-correcting because the EMW software periodically

retries to establish communication with the RAID controller modules in

the storage array. If the storage array was unresponsive and a subsequent

attempt to connect to the storage array succeeds, the storage array

becomes responsive.
For an out-of-band managed storage array, determine if management

operations are taking place on the storage array from other storage

management stations. A RAID controller module-determined limit exists

to the number of Transmission Control Protocol/Internet Protocol

(TCP/IP) connections that can be made to the RAID controller module

before it stops responding to subsequent connection attempts. The type of

management operations being performed and the number of management

sessions taking place together determine the number of TCP/IP

connections made to a RAID controller module. This problem is self-

correcting because, after some TCP/IP connections terminate, the RAID

controller module then becomes responsive to other connection attempts.

23 If the storage array is still unresponsive, a problem may exist with the

RAID controller modules. Contact your Technical Support representative.

book.book Page 263 Tuesday, June 18, 2013 3:09 PM

Advertising
This manual is related to the following products: