Raid controller module-additional features, Battery backup unit, Storage array thermal shutdown – Dell POWERVAULT MD3620I User Manual

Page 34: Raid controller module—additional features

Advertising
background image

34

Planning: RAID Controller Modules

RAID Controller Module—Additional Features

Battery Backup Unit

Each RAID controller contains a two-cell Lithium ion nanopolymer battery

backup unit (BBU). It provides power to the RAID controller module in the

event of a power outage. For information on removing and installing the BBU,

see "RAID Controller Module Backup Battery Unit" on page 232.

NOTE:

For virtual disks, the RAID controller firmware changes the data cache

setting based on the state of the battery. If the battery is missing or does not have

sufficient charge, the controller flushes the cache and sets the write cache

attribute to Write Through for all virtual disks. When the battery is replaced, Write

Back is re-enabled.

Storage Array Thermal Shutdown

The system automatically shuts down when the system temperature exceeds

the safe threshold. The battery backup unit protects against data loss by

providing power to offload to non-volatile memory in the event of power loss.

It is not necessary to shut down any MD1200 Series expansion enclosures

attached to the storage array when thermal shutdown occurs.
Temperature threshold values determine the temperature at which shutdown

occurs. These thresholds cannot be changed.

Table 3-1. Shutdown Threshold Type

Threshold Temperature Exceeding Event Description
Nominal failure threshold

A critical event is set

Maximum failure threshold

The system power supplies shut down within 3

minutes

Shutdown threshold

The system power supplies shut down within 5

seconds

book.book Page 34 Tuesday, June 18, 2013 3:09 PM

Advertising
This manual is related to the following products: