Displaying Failover Alert

You can change the failover alert delay for a storage array. The failover alert

delay lets you delay the logging of a critical event if the multi-path driver

transfers virtual disks to the non-preferred controller. If the multi-path driver

transfers the virtual disks back to the preferred controller within the specified

delay period, a critical event is not logged. If the transfer exceeds this delay

period, then a virtual disk-not-on-preferred-path alert is issued as a critical

event. You can also use this option to minimize multiple alerts when more

than one virtual disk fails over because of a system error, such as a failed host

adapter.
For more information, see the PowerVault Modular Disk Storage Manager

online help topics.

Changing the Cache Settings on the Storage Array

To change the storage array cache settings:

1 In the AMW, select Storage ArrayChangeCache Settings.

The

Change Cache Settings window is displayed.

2 Select or enter the percentage of unwritten data in the cache to trigger a

cache flush in

Start flushing.

3 Select or enter the percentage of unwritten data in the cache to stop a

cache flush in progress in

Stop flushing.

4 Select the appropriate Cache block size.

A smaller cache size is a good choice for file-system use or database-

application use. A larger cache size is a good choice for applications that

generate sequential I/O, such as multimedia.

5 In the Enter Password dialog, type the current password for the storage

array, and click

OK.