Configuring CMC To Send Alerts

You can set alerts and actions for certain events that occur on the managed system. An event occurs when the status of
a system component is greater than the pre-defined condition. If an event matches an event filter and you have
configured this filter to generate an alert (email alert or SNMP trap), then an alert is sent to one or more configured
destinations.
To configure CMC to send alerts:

1.

Enable the global chassis event alerts.

2.

Optionally, you can select the events for which alerts must be generated.

3.

Configure the email alert or SNMP trap settings.

Related Links

Enabling Or Disabling Alerts
Configuring Alert Destinations

Enabling Or Disabling Alerts

To send alerts to configured destinations, you must enable the global alerting option. This property overrides the
individual alert setting.
Make sure that the SNMP or email alert destinations are configured to receive the alerts.

Enabling Or Disabling Alerts Using CMC Web Interface

To enable or disable generating alerts:

1.

In the system tree, go to Chassis Overview, and then click Alerts → Chassis Events.
The Chassis Events page is displayed.

2.

Under Chassis Event Filters Configuration section, select Enable Chassis Event Alerts option to enable alert

generation. Clear this option, to disable the alert generation.

3.

Under the Chassis Event List section, do one of the following:

– Select individual events for which alerts must be generated.
– Select the Enable Alert option on the column header to generate alerts for all events. Else, clear this option.

4.

Click Apply to save the setting.

Enabling Or Disabling Alerts Using RACADM

To enable or disable generating alerts, use the cfgIpmiLanAlertEnable RACAM object. For more information, see the

RACADM Command Line Reference Guide for iDRAC7 and CMC

.

Configuring Alert Destinations

The management station uses Simple Network Management Protocol (SNMP) to receive data from CMC.