IP filtering compares the IP address of an incoming login to the IP address range that is specified. A login from the
incoming IP address is allowed only if both the following are identical:

cfgRacTuneIpRangeMask bit-wise and with incoming IP address

cfgRacTuneIpRangeMask bit-wise and with cfgRacTuneIpRangeAddr

NOTE:

To enable the IP range checking feature, use the following property under cfgRacTuning group:
cfgRacTuneIpRangeEnable <0/1>

To specify the range of IP addresses that you want to block from accessing CMC, use the following property under
cfgRacTuning group:
cfgRacTuneIpRangeAddr

To specify the IP Range Mask that you want to block from accessing CMC, use the following property under
cfgRacTuning group:
cfgRacTuneIpRangeMask

Configuring Virtual LAN Tag Properties for CMC

VLANs are used to allow multiple virtual LANs to co-exist on the same physical network cable and to segregate the
network traffic for security or load management purposes. When you enable the VLAN functionality, each network
packet is assigned a VLAN tag.

Configuring Virtual LAN Tag Properties for CMC Using Web Interface

To configure VLAN for CMC using the CMC Web interface:

1.

Go to any of the following pages:

– In the system tree, go to Chassis Overview and click Network → VLAN.
– In the system tree, go to Chassis Overview → Server Overview and click Network → VLAN.

The VLAN Tag Settings page is displayed. VLAN tags are chassis properties. They remain with the chassis even
when a component is removed.

2.

In the CMC section, enable VLAN for CMC, set the priority and assign the ID. For more information about the fields,

see the

CMC Online Help

.

3.

Click Apply. The VLAN tag settings are saved.
You can also access this page from the Chassis Overview → Servers → Setup → VLAN subtab.

Configuring Virtual LAN Tag Properties for CMC Using RACADM

1.

Enable the VLAN capabilities of the external chassis management network:
racadm config -g cfgLanNetworking -o

cfgNicVLanEnable 1

2.

Specify the VLAN ID for the external chassis management network:
racadm config -g cfgLanNetworking -o cfgNicVlanID <VLAN id>

The valid values for <VLAN id> are 1– 4000 and 4021– 4094. Default is 1.
For example:
racadm config -g cfgLanNetworking -o cfgNicVlanID

1