Understanding redundant cmc environment, Understanding redundant cmc, Environment – Dell POWEREDGE M1000E User Manual

Page 39

Advertising
background image

3.

To enable the user blocking or IP blocking feature, in the Login Lockout Policy section, select Lockout by User

Name or Lockout by IP Address (IPV4) .
The options to set the other login lockout policy attributes are activated.

4.

Enter the required values for login lockout policy attributes in the activated fields — Lockout Fail Count, Lockout

Fail Window , and Lockout Penalty Time. For more information, see the

CMC Online Help

.

5.

To save these settings, click Apply.

Configuring Login Lockout Policy Attributes Using RACADM

You can use RACADM to configure the Login lockout policy attributes for the following features:

User blocking

IP address blocking

Number of login attempts allowed

Timespan for the lockout failure counts to occur

Lockout penalty time

To enable user blocking feature, use:
racadm config -g cfgRacTuning -o cfgRacTuneUserBlkEnable <0|1>

To enable IP blocking feature, use:
racadm config –g cfgRacTuning –o cfgRacTuneIPBlkEnable <0|1>

To specify the number of login attempts, use:
racadm config –g cfgRacTuning –o cfgRacTuneIpBlkFailCount

To specify the time span within which, lockout fail count failures must occur, use:
racadm config –g cfgRacTuning –o cfgRacTuneIpBlkFailWindow

To specify value for lockout penalty time, use:
racadm config –g cfgRacTuning –o cfgRacTuneIpBlkPenaltyTime

For more information about these objects, see the

RACADM Command Line Reference Guide for iDRAC7 and CMC

available at dell.com/support/manuals.

Understanding Redundant CMC Environment

You can install a standby CMC that takes over if your active CMC fails. The redundant CMC may be pre-installed or can
be installed later. It is important that CMC network is properly cabled to ensure full redundancy or best performance.
Failovers can occur when you:

Run the RACADM cmcchangeover command. (See the cmcchangeover command section in the

RACADM Command

Line Reference Guide for iDRAC7 and CMC)

.

Run the RACADM racreset command on the active CMC. (See the racreset command section in the

RACADM

Command Line Reference Guide for iDRAC6 and CMC)

.

Reset the active CMC from Web interface. (See the Reset CMC option for Power Control Operations that is described

in

Executing Power Control Operations

.)

Remove the network cable from the active CMC.

Remove the active CMC from the chassis.

Initiate a CMC firmware flash on the active CMC.

Have an active CMC that is no longer functional.

NOTE: In the event of a CMC failover, all iDRAC connections and all active CMC sessions are lost. Users with

lost sessions must reconnect to the new active CMC.

39