Table 51. PSU Status Screens
Severity
Message
Cause
Critical
Power supply <number> failed.
The PSU has failed.
Critical
The power input for power supply <number> is
lost.
Loss of AC power or AC cord unplugged.
Warning
Power supply <number> is operating at 110 volts,
and could cause a circuit breaker fault.
Power supply is plug into a 110 volt source.
Table 52. Server Status Screen
Severity
Message
Cause
Warning
The system board ambient temperature is less
than the lower warning threshold.
Server temperature is getting cool.
Critical
The system board ambient temperature is less
than the lower critical threshold.
Server temperature is getting cold.
Warning
The system board ambient temperature is
greater than the upper warning threshold.
Server temperature is getting warm.
Critical
The system board ambient temperature is
greater than the upper critical threshold.
Server temperature is getting too hot.
Critical
The system board Current Latch current is
outside of the allowable range
Current crossed a failing threshold.
Critical
The system board battery failed.
CMOS battery is not present or has no voltage.
Warning
The storage battery is low.
ROMB battery is low.
Critical
The storage battery failed.
CMOS battery is not present or has no voltage.
Critical
The CPU <number> <voltage sensor name >
voltage is outside of the allowable range.
Critical
The system board<voltage sensor name >
voltage is outside of the allowable range.
Critical
The mezzanine card <number> <voltage
sensor name > voltage is outside of the
allowable range.
Critical
The storage <voltage sensor name > voltage is
outside of the allowable range.
Critical
CPU <number> has an internal error (IERR).
CPU failure.
Critical
CPU <number> has a thermal trip (over-
temperature) event.
CPU overheated.
Critica
CPU <number> configuration is unsupported.
Incorrect processor type or in wrong location.
Critical
CPU <number> is absent.
Required CPU is missing or not present.