Dell POWEREDGE M1000E User Manual

Page 242

Advertising
background image

Severity

Message

Cause

Critical

Mezz B<slot number> Status: Add-in Card
sensor for Mezz B<slot number>, install error
was asserted.

Incorrect Mezzanine card installed for IO fabric.

Critical

Mezz C<slot number> Status: Add-in Card
sensor for Mezz C<slot number>, install error
was asserted.

Incorrect Mezzanine card installed for IO fabric.

Critical

Drive <number> is removed.

Storage Drive was removed.

Critical

Fault detected on Drive <number>.

Storage Drive failed.

Critical

The system board fail-safe voltage is outside
of the allowable range.

This event is generated when the system board
voltages are not at normal levels.

Critical

The watchdog timer expired.

The iDRAC watchdog timer expires and no action is
set.

Critical

The watchdog timer reset the system.

The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to reboot.

Critical

The watchdog timer powered off the system.

The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to power
off.

Critical

The watchdog timer power cycled the system. The iDRAC watchdog detected that the system has

crashed (timer expired because no response was
received from Host) and the action is set to power
cycle.

Critical

Log is full.

The SEL device detects that only one entry can be
added to the SEL before it is full.

Warning

Persistent correctable memory errors
detected on a memory device at location
<location>.

Warning

Persistent correctable memory error rate has
increased for a memory device at location
<location>.

Correctable ECC errors reach a critical rate.

Critical

Multi-bit memory errors detected on a memory
device at location <location>.

An uncorrectable ECC error was detected.

Critical

An I/O channel check NMI was detected on a
component at bus <number> device <number>
function <number>.

A critical interrupt is generated in the I/O Channel.

Critical

An I/O channel check NMI wa detected on a
component at slot <number>.

A critical interrupt is generated in the I/O Channel.

Critical

A PCI parity error was detected on a
component at bus <number> device <number>
function <number>.

Parity error was detected on the PCI bus.

242