Severity

Message

Cause

Critical

The power supplies are not redundant.
Insufficient resources to maintain normal
operations.

One or more PSU have failed or removed and the
system lacks sufficient power to maintain normal
operations. This could cause servers to power down.

Warning

The control panel ambient temperature is
greater than the upper warning threshold.

Chassis/Enclosure intake temperature exceeded the
warning threshold.

Critical

The control panel ambient temperature is
greater than the upper warning threshold.

Chassis/Enclosure intake temperature exceeded the
warning threshold.

Critical

CMC redundancy is lost.

CMC no longer redundant. This happens if the standby
CMC is removed.

Critical

All event logging is disabled.

The Chassis/Enclosure cannot store events to the
logs. This usually indicates a problem with the control
panel or control panel cable.

Warning

Log is full.

Chassis has detected that only one more entry can be
added to the CEL (hardware log) before it is full.

Warning

Log is almost full.

Chassis event log is 75% full.

Table 48. Fan Status Screens

Severity

Message

Cause

Critical

Fan <number> RPM is operating less than the

lower critical threshold.

The speed of the specified fan is not sufficient to

provide enough cooling to the system.

Critical

Fan <number> RPM is operating greater than the

upper critical threshold.

The speed of the specified fan is too high, usually due

to a broken fan blade.

Table 49. IOM Status Screens

Severity

Message

Cause

Warning

A fabric mismatch detected on I/O module

<number>.

The IO module fabric does not match that of the

server or the redundant I/O module.

Warning

A link tuning failure detected on I/O module

<number>.

The IO module could not be set to correctly use the

NIC on one or more servers.

Critical

A failure is detected on I/O module <number>.

The I/O module has a fault. The same error can also

happen if the I/O module is thermal-tripped.

Table 50. iKVM Status Screen

Severity

Message

Cause

Warning

Console is not available for Local KVM.

Minor failure, such as corrupted firmware.

Critical

Local KVM can not detect any hosts.

USB host enumeration failure.

Critical

OSCAR, on screen display is not functional

for the Local KVM.

OSCAR failure.

Non- Recoverable

Local KVM is not functional, and is powered

off.

Serial RIP failure or USB host chip failure.