Indicators, Codes, and Messages

21

Alert! Current

configuration does not

support redundant memory.

Redundant memory is

disabled.

Memory modules installed are not the
same type and size in all banks; faulty
memory module(s).

This message is not applicable to this
system.

Amount of available memory

limited to 256 MB!

OS Install Mode is enabled in the
System Setup program.

Disable OS Install Mode in the System
Setup program. See "Using the System
Setup program" in the

User's Guide.

Auxiliary device failure

Loose or improperly connected mouse
or keyboard cable; faulty mouse or
keyboard.

See "Troubleshooting the Mouse" and
"Troubleshooting the Keyboard" in
"Troubleshooting Your System."

BIOS Update Attempt

Failed!

Remote BIOS update attempt failed. Retry the BIOS update. If problem

persists, see "Getting Help."

CD-ROM drive not found

IDE CD-ROM Controller option is
enabled in the System Setup program,
but the CD drive is not detected.

If the system does not have a CD drive,
disable the IDE CD-ROM Controller
option in the System Setup program.
See "Using the System Setup program"
in the

User's Guide.

If the system has a CD drive, ensure that
it is properly connected. See
"Troubleshooting a CD Drive" in
"Troubleshooting Your System."

CPUs with different cache

sizes detected

Microprocessors with different cache
sizes are installed.

Ensure that all microprocessors have the
same cache size and that they are
properly installed. See "Processors" in
"Installing System Options."

Decreasing available

memory

Faulty or improperly installed memory
modules.

See "Troubleshooting System Memory"
in "Troubleshooting Your System."

Diskette drive

n seek

failure

Incorrect configuration settings in the
System Setup program.

Run the System Setup program to
correct the settings. See "Using the
System Setup Program" in the

User's

Guide.

Faulty or improperly installed diskette
drive.

See "Troubleshooting a Diskette Drive"
in "Troubleshooting Your System."

Diskette read failure

Faulty or improperly inserted diskette. Replace the diskette.

Diskette subsystem reset

failed

Faulty or improperly installed diskette
drive.

See "Troubleshooting a Diskette Drive"
in "Troubleshooting Your System."

Table 2-8.

System Messages (continued)

Message

Causes

Corrective Actions