Indicators, Codes, and Messages

27

Processor

n internal error

Faulty microprocessor; faulty system
board.

See "Troubleshooting the
Microprocessors" in "Troubleshooting
Your System."

Processor bus parity error

Processor in socket 1 not

installed!

No microprocessor installed in
primary microprocessor socket.

Install a microprocessor in the primary
microprocessor socket. See "Processors"
in "Installing System Options."

Remote access controller

error

Embedded remote access memory
may be temporarily corrupted.

This message is not applicable to this
system.

Remote access controller

is not present

SCSI cable not present on

connector A or B of the

primary backplane

SCSI cable is loose, improperly
connected, or faulty.

This message is not applicable to this
system.

Shutdown failure

Shutdown test failure.

See "Troubleshooting System Memory"
in "Troubleshooting Your System."

Spare bank enabled

Memory spare bank enabled

This message is not applicable to this
system.

System backplane error

Faulty or improperly installed SCSI
backplane board.

This message is not applicable to this
system.

System halted! Must power

down

Wrong password entered too many
times.

Information only.

The amount of system

memory has changed

Memory has been added or removed
or a memory module may be faulty.

If memory has been added or removed,
this message is informative and can be
ignored. If memory has not been added
or removed, check the SEL to determine
if single-bit or multi-bit errors were
detected and replace the faulty memory
module. See "Troubleshooting System
Memory" in "Troubleshooting Your
System."

Time-of-day clock stopped

Faulty battery.

See "Troubleshooting the System
Battery" in "Troubleshooting Your
System."

Time-of-day not set -

please run SETUP program

Incorrect Time or Date settings; faulty
system battery.

Check the Time and Date settings. See
"Using the System Setup Program" in
the

User's Guide. If the problem persists,

replace the system battery. See
"Replacing the System Battery" in
"Installing System Options."

Table 2-8.

System Messages (continued)

Message

Causes

Corrective Actions