Dell PowerEdge 1800 User Manual

Page 24

Advertising
background image

24

Indicators, Codes, and Messages

www

.dell.com | support.dell.com

Invalid NVRAM

configuration, resource

re-allocated

System configuration data has been
ignored.

Check the System Setup configuration
settings. See "Using the System Setup
Program" in the

User's Guide.

Invalid SCSI configuration

SCSI cable detected on

connector SCSIB of the

SCSI backplane, daughter

card not present

A SCSI cable is connected to the
channel B connector on the SCSI
backplane board; SCSI backplane
daughter card is not installed.

This message is not applicable to this
system.

Keyboard controller

failure

Faulty keyboard controller; faulty
system board.

See "Getting Help."

Keyboard clock line

failure

Loose or improperly connected
keyboard cable; faulty keyboard; faulty
keyboard controller.

See "Troubleshooting the Keyboard" in
"Troubleshooting Your System."

Keyboard data line failure

Keyboard failure

Keyboard stuck key failure

Memory address line

failure at

address, read

value expecting value

Faulty or improperly installed memory
modules.

See "Troubleshooting System Memory"
in "Troubleshooting Your System."

Memory double word logic

failure at

address, read

value expecting value

Memory high address line

failure at

start address

to

end address

Memory high data line

failure at

start address

to

end address

Memory odd/even logic

failure at

start address

to

end address

Memory write/read failure

at

address, read value

expecting

value

Table 2-8.

System Messages (continued)

Message

Causes

Corrective Actions

Advertising