Dell PowerEdge 1800 User Manual

Page 23

Advertising
background image

Indicators, Codes, and Messages

23

Error: Incorrect memory

configuration.

Swap the DIMMs in slots

DIMM1_A and DIMM1_B with

DIMMs in slots DIMM2_A and

DIMM2_B.

Memory slots DIMM1_A and
DIMM1_B must be populated with
dual-rank DIMMs if dual-rank
DIMMs are populated in the system.

Swap the memory modules in
DIMM1_A and DIMM1_B with the
memory modules in slots DIMM2_A
and DIMM2_B. See "General Memory
Module Installation Guidelines" in
"Installing System Components."

Error: Maximum PCI option

ROM count exceeded!

Too many expansion cards have ROM
enabled in the System Setup program.

Disable ROM for some of the expansion
cards. See "Using the System Setup
Program" in the

User's Guide.

Gate A20 failure

Faulty keyboard controller; faulty
system board.

See "Getting Help."

Hard disk controller

failure

Incorrect configuration settings in
System Setup program; improperly
installed hard drive, or loose interface
or power cable; faulty hard-drive
controller subsystem.

Run the System Setup program to
correct the drive type. See "Using the
System Setup Program" in the

User's

Guide. If the problem persists, see
"Troubleshooting SCSI Hard Drives" and
"Troubleshooting SATA Hard Drives" in
"Troubleshooting Your System."

Hard disk read failure

I/O parity interrupt at

address

Faulty or improperly installed
expansion card.

See "Troubleshooting Expansion Cards"
in "Troubleshooting Your System."

Invalid configuration

information - please run

SETUP program

Incorrect configuration settings in
System Setup program;
NVRAM_CLR jumper is installed;
faulty system battery.

Check the System Setup configuration
settings. See "Using the System Setup
Program" in the

User's Guide. Remove

the NVRAM_CLR jumper. See
Figure A-2 for jumper location. If the
problem persists, see "Troubleshooting
the System Battery" in "Troubleshooting
Your System."

Table 2-8.

System Messages (continued)

Message

Causes

Corrective Actions