Timer chip counter 2

failed

Faulty system board.

See "Getting Help."

Unsupported CPU

combination

Microprocessor(s) is not supported by
the system.

Install a supported microprocessor
combination. See "Processors" in
"Installing System Options."

Unsupported CPU stepping

detected

Unsupported DIMM detected

in the RAID DIMM slot!

RAID memory module is not
supported by the system.

This message is not applicable to this
system.

Unsupported RAID key

detected!

RAID hardware key is not supported
by the system.

This message is not applicable to this
system.

Utility partition not

available

The <F10> key was pressed during
POST, but no utility partition exists
on the boot hard drive.

Create a utility partition on the boot
hard drive. See "Using the Dell
OpenManage Server Assistant CD" in
your

User's Guide."

The VRM for the processor

in socket

n is not

installed.

Specified microprocessor VRM is
faulty, unsupported, improperly
installed, or missing.

This message is not applicable to this
system.

Warning: Detected mode

change from RAID to SCSI

x

of the embedded RAID

subsystem.

Type of controller has changed from
optional RAID (when available) to
SCSI since previous system boot.

This message is not applicable to this
system.

Warning: Detected mode

change from SCSI to RAID

x

of the embedded RAID

subsystem.

Type of controller has changed from
SCSI to optional RAID (when
available) since previous system boot.

This message is not applicable to this
system.

Warning: Detected missing

RAID hardware for the

embedded RAID subsystem.

Data loss will occur!

Press Y to switch mode to

SCSI, press any other key

to disable both channels.

Press Y to confirm the

change; press any other

key to cancel.

Type of controller has changed since
previous system boot.

This message is not applicable to this
system.

Warning: Firmware is out-

of-date, please update.

Firmware error.

Update the firmware. See "Getting
Help."

Table 2-8.

System Messages (continued)

Message

Causes

Corrective Actions