Indicators, Codes, and Messages

www

.dell.com | support.dell.com

1-2-2

DMA initialization failure

See "Troubleshooting System Memory" in
"Troubleshooting Your System."

1-2-3

DMA page register write/read failure

1-3-1

Main-memory refresh verification
failure

1-3-2

No memory installed

1-3-3

Chip or data line failure in the first
64 KB of main memory

1-3-4

Odd/even logic failure in the first
64 KB of main memory

1-4-1

Address line failure in the first 64 KB
of main memory

1-4-2

Parity failure in the first 64 KB of
main memory

1-4-3

Fail-safe timer test failure

1-4-4

Software NMI port test failure

2-1-1
through
2-4-4

Bit failure in the first 64 KB of main
memory

3-1-1

Slave DMA-register failure

See "Getting Help."

3-1-2

Master DMA-register failure

3-1-3

Master interrupt-mask register failure

3-1-4

Slave interrupt-mask register failure

3-2-2

Interrupt vector loading failure

3-2-4

Keyboard-controller test failure

See "Troubleshooting the Keyboard" in
"Troubleshooting Your System."

Table 2-9.

System Beep Codes (continued)

Code

Cause

Corrective Action