Troubleshooting Your System | 193


3 Enter the System Setup program and check the system memory

settings.
See "System Memory" on page 43. Make any changes to the memory
settings, if needed.
If the memory settings match the installed memory but a problem is
still indicated, go to step 10.

4 Turn off the system and attached peripherals, and disconnect the

system from the electrical outlet.

5 Remove the system-board assembly. See "Removing a System-Board

Assembly" on page 92.

6 Reseat the memory modules in their sockets. See "Installing the

Memory Modules" on page 134.

7 Install the system-board assembly. See "Installing a System-Board

Assembly" on page 93.

8 Reconnect the system to its electrical outlet, and turn on the system

and attached peripherals.

9 Enter the System Setup program and check the system memory

settings. See "System Memory" on page 43.
If the problem is not resolved, proceed with the next step.

10 Turn off the system and attached peripherals, and disconnect the

system from the power source.

11 Remove the system-board assembly. See "Removing a System-Board

Assembly" on page 92.

12 If a diagnostic test or error message indicates a specific memory

module as faulty, swap or replace the module.

13 To troubleshoot an unspecified faulty memory module, replace the

memory module in the first DIMM socket with a module of the same
type and capacity. See "Installing the Memory Modules" on page 134.

14 Install the system-board assembly. See "Removing a System-Board

Assembly" on page 92.