About Your System


Sensor

Sensor Name

Event

Event Log

Sensor Type: Voltage
15h

P3V3

Threshold - 01h

Lower critical threshold is
comparison returned (A, D,
S, R)
Lower non-critical threshold
is comparison returned (A,
D, S, R)
Upper critical going high (A,
D, S, R)
Upper non-critical going high
(A, D, S, R)
Lower critical going low (A,
D, S, R)
Lower non-critical going low
(A, D)
A=3285 D=3285 R=1b1b

Sensor Type: Fan
6Bh
6Ch
6Dh
6Eh

FCB_FAN1
FCB_FAN2
FCB_FAN3
FCB_FAN4

Threshold - 01h

Lower critical threshold is
comparison returned (A, D,
S, R)
Lower non-critical threshold
is comparison returned (A,
D, S, R)
Lower critical going low (A,
D, S, R)
Lower non-critical going low
(A, D)
A=7005 D=7005 R=0303

Sensor Type: Current
CAh

MB_12V_Current

Threshold –
01h

A=0000 D=0000 R=0000

70h
71h

PSU1_OUT_Current
PSU2_OUT_Current

Threshold –
01h

A=0000 D=0000 R=0000