Dell POWEREDGE C6105 User Manual

Page 39

Advertising
background image

Using the System Setup Program | 39


3 Enter Set BMC LAN Configuration screen and verify the following

settings:

Remote Access: enabled

Serial port number: COM2

Serial Port Mode: 115200 8,n,1

Flow Control: None

Redirection After BIOS POST: Always

Terminal Type: ANSI

To do this, see ―Remote Access Configuration‖ on page 62. Note that the
last four options need to sync with the host and client.
4 Enter LAN Configuration screen and verify the following settings:

BMC LAN Port Configuration: Dedicated-NIC

DHCP Enabled: Disabled or Enabled (Enabled if DHCP server
support)

IP Address: 192.168.001.003

Subnet Mask: 255.255.255.000

Gateway Address: 000.000.000.000

To do this, see ―LAN Configuration‖ on page 61. Note that the host and
client need to have the same network section.

To enable SOL feature in the mode of Shared-NIC, please perform the
following steps:
1 Connect the LAN cable to NIC1 connector. For location of NIC1

connector on the back panel, see Figure 1-6 item 5.

2 Enter the server BIOS setup screen.
3 Enter Set BMC LAN Configuration screen and verify the following

settings:

Remote Access: enabled

Serial port number: COM2

Serial Port Mode: 115200 8,n,1

Flow Control: None

Redirection After BIOS POST: Always

Terminal Type: ANSI