Troubleshooting a storage controller – Dell POWEREDGE C6105 User Manual

Page 195

Advertising
background image

Troubleshooting Your System | 195


d. Exit the configuration utility and allow the system to boot to the

operating system.

2 Ensure that the required device drivers for your controller card are

installed and are configured correctly. See the operating system
documentation for more information.

3 Restart the system, enter the System Setup program, and verify that

the controller is enabled and the drives appear in the System Setup
program.
See "Using the System Setup Program‖ on page 37.
If the problem persists, see "Getting Help" on page 215.

Troubleshooting a Storage Controller

NOTE: When troubleshooting a SAS RAID controller, also see the
documentation for your operating system and the controller.

1 Enter the System Setup program and ensure that the SAS controller is

enabled. See "Using the System Setup Program" on page 37.

2 Restart the system and press the applicable key sequence to enter the

configuration utility program.

<Ctrl><C> for a SAS 2008 daughter card

<Ctrl><H> for a LSI 9260-8i card or a LSI 9265-8i card

See the controller's documentation for information about configuration
settings.

3 Check the configuration settings, make any necessary corrections, and

restart the system.

CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came with
the product.