Using the System Setup Program | 67


To check token active status:
./syscfg --istokenactive=D4_token_id

(Example: ./syscfg --istokenactive=0x002D to check the token
active status of NIC1)

To change the SETUP option thru BMC memory directly:
./ipmitool raw <command> <data>

(Example: ./ipmitool raw 0xc 1 1 3 10 106 42 120 to set IP address
of BMC LAN port as 10.106.42.120)

The D4 token table
Token Setup option

Description

002D

NIC1 - 82576

Enable the system‘s primary embedded network
interface controller (full-function), including its PXE
boot-ROM.

002E

NIC1 - 82576

Disable the system‘s primary embedded network
interface controller.

006E

NIC1 - 82576

Enable the system‘s primary embedded network
interface controller, but don‘t enable the NIC‘s
associated PXE or RPL boot-ROM.

0051

1st Boot Device

Set the diskette device to be inserted as the first
device in the boot sequence.

0052

1st Boot Device

Only the hard drive can be in the boot sequence

0053

1st Boot Device

Boot seq device list.

0054

1st Boot Device

Set the CDROM to be inserted as the first device in
the boot sequence.

0087

Video Enumeration The onboard video controller is used for boot-time

messages.

0088

Video Enumeration The first add-in video controller is used for boot-time

messages. Depending on the BIOS search order and
system slot layout.

00A1

Restore on AC
Power Loss

After an AC power loss, when AC power is restored,
the system stays off.