- Digital Fiber Sensor FS-N10 Series User's Manual -

This function calibrates the current value to "

.0

". After the preset function has been

executed with "

100.0

" displayed, and then executing this function with "

.0

" displayed, 2

random set points can be calibrated to "

100.0

" and "

.0

".

* Not available for the FS-N10 Series shipped before March 10, 2011.

Enabling the work-preset function

The work-preset function can be used with the preset function (when
preset is enabled).

While the preset function is enabled, press the [PRESET] button and

button

simultaneously.

The received light intensity
at that point is set to "

.0

".

The value set to "

100.0

" using

the preset function does not
change.

Even if the received light intensity is low during preset and is high during
work-preset, the value is set to "

100.0

" during preset and "

.0

" during work-

preset. When the actual received light intensity increases, the display will
approach "

.0

". (The preset saturation level is decreased with respect to

"

100.0

".)

Disabling the work-preset function

When the PST indicator is lit, press and hold the [PRESET] button.

• The PST indicator turns off, indicating that the work-preset function has been

disabled.

Work-Preset Function

Impotant

Green "PST"
lights up

Current value is "

.

0

"

100.0

PRESET +

3.0

.0

Reference